This test method is applicable to firestop systems of various materials and construction. Firestop systems are intended for use in openings in fire-resistive walls. Everkem Firestop+ ASTM E Elastomeric Intumescent Fire Stop Caulk for a wide range of electrical, plumbing, HVAC and head-of-wall applications. Tested and Listed Systems – ASTM E / UL -. UL , ULC-S, ASTM E • Professional Installation – FCIA Member,. FM

Author: Zulut Kazrajinn
Country: Slovenia
Language: English (Spanish)
Genre: Art
Published (Last): 15 August 2006
Pages: 150
PDF File Size: 13.9 Mb
ePub File Size: 4.75 Mb
ISBN: 844-6-49430-451-6
Downloads: 43496
Price: Free* [*Free Regsitration Required]
Uploader: Mezigar

These notes and footnotes excluding those in tables and figures shall not be considered requirements of the standard. These notes and footnotes excluding those in tables and figures shall not be considered requirements of the standard.

However, this test method shall not be construed as determining the performance of the firestop system during actual fire conditions when subjected to forces such as failure of cable support systems and falling debris. Firestop systems are intended for use in openings in fire-resistive walls and floors that are evaluated in accordance with Test Methods E Active view current version of standard.

  APRESS GIMP FOR ABSOLUTE BEGINNERS PDF

However, this test method shall not be construed as determining the performance of the firestop system during actual fire conditions when subjected to forces such as failure of cable support systems and falling debris. Link to Active This link will always route to the current Active version of the standard.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not asrm standard.

ASTM E814 – 13a(2017)

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. An F rating shall be based upon flame occurrence on the unexposed surface, while the T rating shall be based upon the xstm rise as well as flame occurrence on the unexposed side of the firestop system.

Link to Active This link will always route to the current Active version of the standard. Historical Version s – view previous versions of standard.

Firestop+ ASTM-E Elastomeric Intumescent Fire stop Caulk

Referenced Documents purchase separately The documents listed below are referenced within the subject standard ee814 are not provided as part of the standard. These ratings, together with detailed performance data such as the location of through-openings and temperatures of penetrating items are intended to be one factor in assessing performance of firestop systems.

  ANTIBIOTIQUES EN PARODONTOLOGIE PDF

D814 is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The performance of a firestop system is dependent upon the specific assembly of materials tested including the number, type, and size of penetrations and the floors or walls in which it is installed.

Firestop systems are intended for use in openings in fire-resistive walls and floors that are evaluated e841 accordance with Test Methods E The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.