ABB ACS350 MANUAL PDF

View and Download ABB ACS user manual online. ACS Inverter pdf manual download. Document library, contact your local ABB representative. FENA/ Ethernet adapter module user’s manual ACS, ACS and ACS ABB ACS Users Guide – Free ebook download as PDF File .pdf), Text File . txt) or read book ACS Drives 22 kW 30 HP User’s Manual.

Author: Voodookora Gardalar
Country: Namibia
Language: English (Spanish)
Genre: Software
Published (Last): 6 July 2012
Pages: 121
PDF File Size: 4.15 Mb
ePub File Size: 7.52 Mb
ISBN: 881-4-40656-298-3
Downloads: 78522
Price: Free* [*Free Regsitration Required]
Uploader: Fauhn

Drive is stopped with ramp pair 1. Protection against short-circuit in the motor and motor cable The drive protects the motor and motor cable in a short-circuit situation when the motor cable is dimensioned according to the nominal current of the drive.

ABB ACS350 – 7.5kW 230V 3ph to 3ph – AC Inverter Drive Speed Controller

By default, the display shows three signals. Mqnual the new setting by pressing If you want to monitor actual values during the ID Run, go to the Output mode by pressing repeatedly until you get there. Table Of Contents AC power line connection Operation time scheme The time scheme below illustrates the operation of the brake control function. Drive is programmed for traverse control with 30 sequences. Tightening torque is 0.

ABB ACS – kW V 3ph to 3ph – AC Inverter Drive Speed Controller – AC Inverter Drives (V)

The Fieldbus Control Interface The fieldbus control interface The communication between a fieldbus system and the drive consists of bit input and output data words with ABB Drives profile and bit input and output words with DCU profile.

  CROTON URUCURANA PDF

Drive is accelerated to 20 Hz with 60 s ramp time.

In the Copy mode, you can do the following: Page The drive can be connected to an external control system via a fieldbus adapter or embedded fieldbus. However, it might be useful at this stage to set the parameters required by your application and save the settings as a user macro as instructed in section If sequence programming is deactivated by falling edge of digital input DI1, state machine is reset to state 1.

The work described in this chapter may only be carried out by a qualified electrician. As default all sequence programming parameters can be changed even when the sequence programming is active. If the measured tension exceeds the tension setpoint, the speed will be slightly decreased, and vice versa.

ABB ACS350 User Manual

Operation and start-up These warnings are intended for all who plan the operation, start up or operate the drive. How to perform the guided start-up To be able to perform the guided start-up, you need the Assistant Control Panel. When both the reference DC Hold and the motor speed fall below the preset DC hold speed, the drive stops the motor and starts to inject DC DC hold speed into the motor. Start, stop, direction so Amendment A1 Provisions for compliance: Select the motor control mode parameter Covers on R0 and R1.

  LIVRO MOONWALK PDF

ABB ACS USER MANUAL Pdf Download.

Embedded fieldbus or an optional fieldbus adapter enables control over an open fieldbus link. Control Cable Ducts A diagram of the cable routing is shown below. Two units with the same address are not allowed on-line.

Example The drive runs a conveyor line. Guarantees the best possible control accuracy. The Type function is useful in applications with high break-away torque when vector dependent Fuses must be used with other circuit breakers.

LOC indicates local control on the panel display. Current and power The current and power ratings are given below. The longer the derivation time, the more the speed controller output is boosted during the change. Actual Signals Actual signals Several actual signals are available: Can be monitored by the user. When frequency falls below the set level during run, the brake is closed. Page Fan failure can be predicted by the increasing noise from the fan bearings.

How to get help Step Action Display Press to read the context-sensitive help text for the item that is highlighted. How to set the speed, frequency or torque reference Step Action Display Go to the Main menu by pressing if you are in the Output mode,